A Method for Intelligent Allocation of Diagnostic Testing by Leveraging Data from Commercial Wearable Devices: A Case Study on COVID-19.

TitleA Method for Intelligent Allocation of Diagnostic Testing by Leveraging Data from Commercial Wearable Devices: A Case Study on COVID-19.
Publication TypeJournal Article
Year of Publication2022
AuthorsJ Dunn, MH Shandhi, P Cho, A Roghanizad, K Singh, W Wang, O Enache, A Stern, R Sbahi, B Tatar, S Fiscus, QX Khoo, Y Kuo, X Lu, J Hsieh, A Kalodzitsa, A Bahmani, A Alavi, U Ray, M Snyder, G Ginsburg, D Pasquale, C Woods, and R Shaw
JournalRes Sq
Date Published04/2022
Abstract

Mass surveillance testing can help control outbreaks of infectious diseases such as COVID-19. However, diagnostic test shortages are prevalent globally and continue to occur in the US with the onset of new COVID-19 variants, demonstrating an unprecedented need for improving our current methods for mass surveillance testing. By targeting surveillance testing towards individuals who are most likely to be infected and, thus, increasing testing positivity rate (i.e., percent positive in the surveillance group), fewer tests are needed to capture the same number of positive cases. Here, we developed an Intelligent Testing Allocation (ITA) method by leveraging data from the CovIdentify study (6,765 participants) and the MyPHD study (8,580 participants), including smartwatch data from 1,265 individuals of whom 126 tested positive for COVID-19. Our rigorous model and parameter search uncovered the optimal time periods and aggregate metrics for monitoring continuous digital biomarkers to increase the positivity rate of COVID-19 diagnostic testing. We found that resting heart rate features distinguished between COVID-19 positive and negative cases earlier in the course of the infection than steps features, as early as ten and five days prior to the diagnostic test, respectively. We also found that including steps features increased the area under the receiver operating characteristic curve (AUC-ROC) by 7-11% when compared with RHR features alone, while including RHR features improved the AUC of the ITA model's precision-recall curve (AUC-PR) by 38-50% when compared with steps features alone. The best AUC-ROC (0.73 ± 0.14 and 0.77 on the cross-validated training set and independent test set, respectively) and AUC-PR (0.55 ± 0.21 and 0.24) were achieved by using data from a single device type (Fitbit) with high-resolution (minute-level) data. Finally, we show that ITA generates up to a 6.5-fold increase in the positivity rate in the cross-validated training set and up to a 3-fold increase in the positivity rate in the independent test set, including both symptomatic and asymptomatic (up to 27%) individuals. Our findings suggest that, if deployed on a large scale and without needing self-reported symptoms, the ITA method could improve allocation of diagnostic testing resources and reduce the burden of test shortages.

DOI10.21203/rs.3.rs-1490524/v1
Short TitleRes Sq